877-41 SCALE (72253), 973-216-6739 sales@globalscaleco.com

Rice Lake, DIGI® S-T-U-V

$608.00$904.00

  • IP66 rated
  • Platform support in each corner
  • Shock resistant load cells
  • Rated to 300% overload
  • *Non NTEP

 

Specification
SKU: rice-lake-digi®-s-t-u-v Category: Tags: ,

Available Options:

Description

The DIGI S Series bench scale bases are designed for endurance with a 300% overload rating an IP66-rated design. Shock-resistant load cells withstand damage from harsh loading and include platform corner support. Multiple mid-size base dimensions and capacities are available up to 1500 pounds.

Recommended Exc. Voltage:
5-12 VDC

Max Exc. Voltage:
20 VAC/DC

Output Impedance:
350 ±10 Ω

Insulation Resistance:
500 MΩ or more

Rated Output:
0.83 mV/V ±7.5%

Rated Input:
1 mV/V ±7.5%

Load Cell Cable Length:
S-S/S-T: 9 ft (3 m) with 14 pin connector
S-U: 18 ft (5.5 m) with 14 pin connector
S-V: 28 ft (8.5 m) with 14 pin connector

Temperature Range:
14˚ F to 104˚ F (-10˚ C to 40˚ C)

Warranty:
Two-year limited warranty

Approvals:
NTEP CC 02-111, Class III, 5000 d
Measurement Canada AM-5393, Class III 5,000 d

Additional information

Weight135 lbs
Platform size

17 x 21 x 4.5 in, 24 x 28 x 6 in, 24 x 28 x 5 in, 13 x 17 x 3.5 in

Model

S-UL, S-VL, S-TL, S-SL

Capacity